100G Integrated WDM Device
The 100G Integrated WDM Device is a box-type, high-density DCI transport platform for data centre interconnection. A single 1U unit delivers high-capacity transport, scaling further per fibre pair through device stacking. High-density optoelectronic integration avoids complex patch-fibre cabling and switch-style connections, forming an end-to-end wavelength-division link with a simple, plug-and-play management model, well suited to data-centre rooms and metro DCI bearer networks.
Highlights
High-density 1U box
Stackable box-type form factor, no rack space wasted, easy to relocate.
1.2Tbps per device
12×100G in 1U, extendable to 2.4Tbps per fibre pair by stacking two units.
Mixed service transport
Transparent 40GE/100GE transmission, with service interfaces and counts customisable to order.
Isolated, secure ports
No complex optical/electrical crossover; each service port is physically isolated for network security.
Drop-in network integration
No change to existing topology or optical layer design, just select the model for the required span/attenuation.
1+1 line protection
Automatic route selection on the fibre side for network reliability.
Zero-touch deployment
Delivered pre-configured, power-up free, plug-and-play, with no manual fibre patching.
In-band SNMP management
In-band monitoring channel carries whole-network SNMP management over the optical path itself.
Application Scenario
Format
Specifications
| Capacity & Ports | |||
|---|---|---|---|
| Maximum Capacity per Device | 1.2Tbps (12×100G), 1RU | ||
| Maximum Capacity per Fibre | 2.4Tbps, via 2×1RU device stacking | ||
| Maximum Rate per Port | 100Gbit/s | ||
| Service Port Type | 40G/100G QSFP optical port (fixed interface type) | ||
| Ports per Device | 4, 8 or 12×QSFP optical ports, see Port Count table below | ||
| Supported Service Types | 40GE, 100GE (per service port type) | ||
| Protection & Management | |||
| Network-Level Protection | Line-side 1+1 protection with automatic route selection | ||
| Device-Level Protection | Power supply 1+1 hot backup (two-unit configurations) · 4× fan hot backup | ||
| Management Style | Web GUI · network management system (in-band SNMP) | ||
| Power & Mechanical | |||
| Device Size | 1U: 44mm (H) × 442mm (W) × 600mm (D) | ||
| Installation | 19″ server cabinet | ||
| Power Supply | 1 or 2 hot-swappable units, 1+1 hot backup with load sharing · AC 90–260V · DC −36 to −72V · high-voltage DC optional | ||
| Heat Dissipation | Front and rear airflow, 4× hot-swappable fan units | ||
| Power Consumption | <400W (full load) | ||
| Operating Temperature | −5°C–50°C (typical) | ||
| Operating Humidity | 5%–95%, non-condensing | ||
| Storage Temperature | −40°C–85°C | ||
Port Count
| Code | Ports | Aggregate capacity |
|---|---|---|
| 4 | 4×QSFP (100G) | 400Gbps |
| 8 | 8×QSFP (100G) | 800Gbps |
| 12 | 12×QSFP (100G) | 1.2Tbps |
Grid
| Code | ITU-T grid | Role |
|---|---|---|
| E | Even grid, 100GHz | Primary device on the fibre pair |
| O | Odd grid, 100GHz (offset 50GHz from Even) | Second device stacked on the same fibre pair, interleaved with the Even device for 50GHz spacing, doubling capacity to 2.4Tbps |
Ordering Information
| Name | 100G Integrated WDM Device |
| Description | 100G Integrated WDM Device, box-type, high-density 1U DCI transport platform. QSFP ports at 40G/100G, scaling to 2.4Tbps per fibre via device stacking. Transparent 40GE/100GE service transport with physically isolated ports, 1+1 line protection with automatic route selection, in-band SNMP management, plug-and-play zero-touch deployment, hot-swappable AC/DC power, one or two units (1+1 redundant with two). |
| Part Number | WDM-IWD-100G-{Ports}-{Grid}-{PSU}-1U |
| {Ports} | 4 · 8 · 12, see Port Count table above, required | |||||||||||||
| {Grid} | E · O, see Grid table above, required — stack an E unit with an O unit on the same fibre pair to reach 2.4Tbps | |||||||||||||
| {PSU} |
|