OTN SystemsWDM Platforms

100G Integrated WDM Device

The 100G Integrated WDM Device is a box-type, high-density DCI transport platform for data centre interconnection. A single 1U unit delivers high-capacity transport, scaling further per fibre pair through device stacking. High-density optoelectronic integration avoids complex patch-fibre cabling and switch-style connections, forming an end-to-end wavelength-division link with a simple, plug-and-play management model, well suited to data-centre rooms and metro DCI bearer networks.

100G Integrated WDM Device

High-density 1U box

Stackable box-type form factor, no rack space wasted, easy to relocate.

1.2Tbps per device

12×100G in 1U, extendable to 2.4Tbps per fibre pair by stacking two units.

Mixed service transport

Transparent 40GE/100GE transmission, with service interfaces and counts customisable to order.

Isolated, secure ports

No complex optical/electrical crossover; each service port is physically isolated for network security.

Drop-in network integration

No change to existing topology or optical layer design, just select the model for the required span/attenuation.

1+1 line protection

Automatic route selection on the fibre side for network reliability.

Zero-touch deployment

Delivered pre-configured, power-up free, plug-and-play, with no manual fibre patching.

In-band SNMP management

In-band monitoring channel carries whole-network SNMP management over the optical path itself.

DC-1 DC-2 IWD-100G IWD-100G stacked (2×1U) IWD-100G IWD-100G stacked (2×1U) Main Backup 2.4Tbps NMS Two stacked units per site combine Main and Backup fibres into a single 2.4Tbps protected link, managed in-band via NMS.
1U
Capacity & Ports
Maximum Capacity per Device1.2Tbps (12×100G), 1RU
Maximum Capacity per Fibre2.4Tbps, via 2×1RU device stacking
Maximum Rate per Port100Gbit/s
Service Port Type40G/100G QSFP optical port (fixed interface type)
Ports per Device4, 8 or 12×QSFP optical ports, see Port Count table below
Supported Service Types40GE, 100GE (per service port type)
Protection & Management
Network-Level ProtectionLine-side 1+1 protection with automatic route selection
Device-Level ProtectionPower supply 1+1 hot backup (two-unit configurations) · 4× fan hot backup
Management StyleWeb GUI · network management system (in-band SNMP)
Power & Mechanical
Device Size1U: 44mm (H) × 442mm (W) × 600mm (D)
Installation19″ server cabinet
Power Supply1 or 2 hot-swappable units, 1+1 hot backup with load sharing · AC 90–260V · DC −36 to −72V · high-voltage DC optional
Heat DissipationFront and rear airflow, 4× hot-swappable fan units
Power Consumption<400W (full load)
Operating Temperature−5°C–50°C (typical)
Operating Humidity5%–95%, non-condensing
Storage Temperature−40°C–85°C
CodePortsAggregate capacity
44×QSFP (100G)400Gbps
88×QSFP (100G)800Gbps
1212×QSFP (100G)1.2Tbps
CodeITU-T gridRole
EEven grid, 100GHzPrimary device on the fibre pair
OOdd grid, 100GHz (offset 50GHz from Even)Second device stacked on the same fibre pair, interleaved with the Even device for 50GHz spacing, doubling capacity to 2.4Tbps
Name100G Integrated WDM Device
Description100G Integrated WDM Device, box-type, high-density 1U DCI transport platform. QSFP ports at 40G/100G, scaling to 2.4Tbps per fibre via device stacking. Transparent 40GE/100GE service transport with physically isolated ports, 1+1 line protection with automatic route selection, in-band SNMP management, plug-and-play zero-touch deployment, hot-swappable AC/DC power, one or two units (1+1 redundant with two).
Part NumberWDM-IWD-100G-{Ports}-{Grid}-{PSU}-1U
{Ports}4 · 8 · 12, see Port Count table above, required
{Grid}E · O, see Grid table above, required — stack an E unit with an O unit on the same fibre pair to reach 2.4Tbps
{PSU}
CodeMeaning
DCOne DC power supply unit
ACOne AC power supply unit
ADOne DC + one AC unit, mixed
2DTwo DC units, 1+1 redundant
2ATwo AC units, 1+1 redundant
Required. Two units (1+1) are recommended.
© Nexgen A/S, OTN WDM platformDatasheet Version 1.0.0 (Released) · 16 Nov 2026nexgen.eu · customer.service@nexgen.eu