This 1U optoelectronic-integrated OTN DCI platform provides four service-card slots and one dedicated management slot, targeting high-density data center interconnection in space-constrained racks. It carries up to 800G per wavelength and 6.4 Tbit/s per subrack, with highly integrated optical-layer functions and configurable power/fan redundancy.
Compact 1U interconnect
Four service-card slots deliver up to 6.4 Tbit/s per subrack and up to 32 Tbit/s per fibre pair on the C-band (400G × 80λ or 800G × 40λ), in a space-efficient 1U footprint for growing DCI links.
800G-ready, evolving further
Supports coherent line rates up to 800G per wavelength today (PDMPDM: Polarization Division MultiplexingSends two independent streams on the two light polarizations, doubling capacity.-16QAM16QAM: Quadrature Amplitude ModulationCoherent modulation combining phase and amplitude; 8QAM and 16QAM carry more bits per symbol over shorter reach.), on a platform designed to evolve toward 1.2T and 1.6T per wavelength.
Highly integrated optical layer
Consolidates OAOA: Optical AmplifierGeneric term for a device that boosts an optical signal., WSSWSS: Wavelength Selective SwitchRoutes each wavelength independently to the chosen output port; the core of a ROADM., VOAVOA: Variable Optical AttenuatorAdjustable attenuator that lowers signal power to the level expected by the next equipment., OSCOSC: Optical Supervisory ChannelDedicated wavelength (typically 1510nm) carrying management data between sites, separate from client traffic., OTDROTDR: Optical Time Domain ReflectometerSends light pulses into the fibre and analyses the reflections to locate breaks, splices and losses., OCMOCM: Optical Channel MonitorMeasures the power and wavelength of each channel of a DWDM signal. and OLPOLP: Optical Line ProtectionSwitches traffic to a backup fibre when the main fibre line fails or degrades. functions on the optical layer board, simplifying internal fibre connections and easing deployment.
Any-service, transparent access
Transparently transports Ethernet up to 400GbE, SDHSDH: Synchronous Digital HierarchyLegacy telecom transport standard, still widely used by operators./SONETSONET: Synchronous Optical NetworkingNorth American equivalent of SDH., Fibre Channel up to 3200 and OTU1OTU1: Optical channel Transport UnitOTN framing level defined by ITU-T G.709 (OTU2 about 10.7G, OTU4 about 112G), with error correction and management overhead./2/2e/4, with hot-swappable, pluggable modular cards.
Efficient device-level resilience
Optical line, multiplex-section and channel protection combine with 1+1 CRPSCRPS: Common Redundant Power SupplyStandardised hot-swappable redundant power supply format. power (AC/HVDCHVDC: High-Voltage Direct CurrentHigh-voltage DC power feed (e.g. 240V DC) used in some data centers./DC) and 1+1 rear fan backup around a single, hot-swappable main control board.
| Rack Units | 1U |
| Dimensions (H×W×D) | 44 × 444 × 490 mm |
| Service Slots | 4 |
| Management Slots | 1, dedicated to the NMC card, separate from the service slots |
| Maximum Power Consumption | < 550 W (typical) |
| Mounting | 19-inch rack, 800 mm+ depth |
| Cooling | Front-to-back airflow, 1+1 hot-swappable fan backup |
| Power Input | AC 90–264V (100–130V / 200–240V rated) or DC -40 to -72V, AC and DC units combinable |
| Power Feed | Rear, standard CRPSCRPS: Common Redundant Power SupplyStandardised hot-swappable redundant power supply format. power supply 1+1 backup |
| Maximum Capacity | 6.4 Tbit/s per subrack · 32 Tbit/s per fibre pair (C-band, 400G × 80λ or 800G × 40λ) |
| Maximum Single-Channel Rate | 800 Gbit/s (PDMPDM: Polarization Division MultiplexingSends two independent streams on the two light polarizations, doubling capacity.-16QAM16QAM: Quadrature Amplitude ModulationCoherent modulation combining phase and amplitude; 8QAM and 16QAM carry more bits per symbol over shorter reach.) |
| Line Rates | | Rate | Modulation |
|---|
| 10G | NRZNRZ: Non-Return-to-ZeroSimple binary modulation (one bit per symbol) used up to about 10G per lane. | | 100G | PDMPDM: Polarization Division MultiplexingSends two independent streams on the two light polarizations, doubling capacity.-QPSKQPSK: Quadrature Phase Shift KeyingCoherent phase modulation carrying two bits per symbol; the most robust format for long distances. | | 200G | PDMPDM: Polarization Division MultiplexingSends two independent streams on the two light polarizations, doubling capacity.-QPSKQPSK: Quadrature Phase Shift KeyingCoherent phase modulation carrying two bits per symbol; the most robust format for long distances. | | PDMPDM: Polarization Division MultiplexingSends two independent streams on the two light polarizations, doubling capacity.-8QAM8QAM: Quadrature Amplitude ModulationCoherent modulation combining phase and amplitude; 8QAM and 16QAM carry more bits per symbol over shorter reach. | | PDMPDM: Polarization Division MultiplexingSends two independent streams on the two light polarizations, doubling capacity.-16QAM16QAM: Quadrature Amplitude ModulationCoherent modulation combining phase and amplitude; 8QAM and 16QAM carry more bits per symbol over shorter reach. | | 300G | PDMPDM: Polarization Division MultiplexingSends two independent streams on the two light polarizations, doubling capacity.-8QAM8QAM: Quadrature Amplitude ModulationCoherent modulation combining phase and amplitude; 8QAM and 16QAM carry more bits per symbol over shorter reach. | | 400G | PDMPDM: Polarization Division MultiplexingSends two independent streams on the two light polarizations, doubling capacity.-16QAM16QAM: Quadrature Amplitude ModulationCoherent modulation combining phase and amplitude; 8QAM and 16QAM carry more bits per symbol over shorter reach. | | PDMPDM: Polarization Division MultiplexingSends two independent streams on the two light polarizations, doubling capacity.-QPSKQPSK: Quadrature Phase Shift KeyingCoherent phase modulation carrying two bits per symbol; the most robust format for long distances. | | 800G | PDMPDM: Polarization Division MultiplexingSends two independent streams on the two light polarizations, doubling capacity.-16QAM16QAM: Quadrature Amplitude ModulationCoherent modulation combining phase and amplitude; 8QAM and 16QAM carry more bits per symbol over shorter reach. |
|
| Supported Services | Ethernet FEFE: Fast EthernetEthernet at 100 Mbit/s./GbE/10/25/40/100/400GbE (100GbE FlexEFlexE: Flexible EthernetOIF standard that decouples the Ethernet client rate from the physical link, for bonding, sub-rating or channelisation.-unaware) · SDHSDH: Synchronous Digital HierarchyLegacy telecom transport standard, still widely used by operators. STMSTM: Synchronous Transport ModuleSDH rate levels: STM-1 155M, STM-4 622M, STM-16 2.5G, STM-64 10G.-1/4/16/64 · Fibre Channel 100/200/800/1200/1600/3200 · OTU1OTU1: Optical channel Transport UnitOTN framing level defined by ITU-T G.709 (OTU2 about 10.7G, OTU4 about 112G), with error correction and management overhead./2/2e/4 |
| Maximum Number of Wavelengths | 120 waves, fixed 50 GHz grid |
| Channel Spacing | Fixed grid, 50/75/100/150 GHz |
| Frequency / Wavelength Range | 190.7–196.65 THz / 1524.5–1572.06 nm |
| Network-Level Protection | Optical line protection (OLPOLP: Optical Line ProtectionSwitches traffic to a backup fibre when the main fibre line fails or degrades.) · optical multiplex-section protection (OMSPOMSP: Optical Multiplex Section ProtectionProtects the whole multiplexed DWDM signal at once by switching it to a backup path.) · optical channel protection (OChP) |
| Device-Level Protection | Single hot-swappable NMCNMC: Network Management CardChassis card providing the management interfaces (SNMP, web, NMS). card · power supply redundancy per selected configuration · fan 1+1 · board-level 1+1 (select cards) |
| Network Management | CLICLI: Command Line InterfaceText-based configuration interface. · Web LCTLCT: Local Craft TerminalLocal management tool, such as a web interface, used by a technician on site. · SNMP · NETCONF/YANG · GUI (B/S architecture) · DCNDCN: Data Communication NetworkManagement network linking equipment to the NMS, separate from client traffic. over OSCOSC: Optical Supervisory ChannelDedicated wavelength (typically 1510nm) carrying management data between sites, separate from client traffic. |
| Operating Temperature | -5°C to +45°C (short term) · 0°C to +40°C (long term) |
| Operating Humidity | 5–95%, non-condensing |
| Storage Temperature | -40°C to +70°C |