Skip to Content

Optical Line Protection Card for DCI Chassis

https://nexgen1.odoo.com/web/image/product.template/10539/image_1920?unique=9931463

The Optical Protection Card assists a wavelength-division system with optical-layer 1+1 protection, monitoring the working and backup route signal status in real time. If the optical signal is interrupted or degrades, it automatically switches between the working and backup routes so the system's optical signal recovers within milliseconds - entirely at the optical layer, with no dependency on higher-layer service protection.

1+1 optical protection

Bidirectional protection of a duplex fibre pair: the transmit signal is split onto the main and backup routes, and each end independently selects the better received signal (single-end switching, no signalling between ends).

Fast, pure-optical switching

Switching time <5ms, entirely at the optical layer - no dependency on higher-layer protocols.

1 or 2 protection groups

Supports 1 or 2 groups of optical protection modules on a single 1-slot card, selectable by application scenario.

Wide protection scenarios

Optical line 1+1 protection (OLP), optical multiplex section protection (OMSP), and optical channel protection (OCHP).

Real-time power monitoring

Continuous monitoring of working and backup route optical power, ±0.5dBm accuracy above -25dBm.

High isolation

>50dB isolation between paths for reliable route discrimination.

LINE1(IN)LINE1(OUT)LINE2(IN)LINE2(OUT)MAIN LINE 1(OUT)MAIN LINE 1(IN)BACKUP LINE 1(OUT)BACKUP LINE 1(IN)MAIN LINE 2(OUT)MAIN LINE 2(IN)BACKUP LINE 2(OUT)BACKUP LINE 2(IN)

Diagram shows the 2-group configuration (LINE1 and LINE2), each with its own MAIN and BACKUP route switching; the 1-group variant populates only the LINE1 pair.

CARD FOR DCI CHASSIS1 SLOT

0.00 kr 0.0 DKK 0.00 kr

  • Number of Protection Groups

This combination does not exist.

Function1+1 protection of optical signals, dual-transmit selective reception, single-end switching
DirectionBidirectional, each protection group protects a duplex fibre pair (TX and RX) over the main and backup routes. Single-ended switching: each end selects its receive path independently, with no signalling between ends.
Slots Occupied1
Integration1 or 2 groups of optical protection modules (selectable by application scenario)
Working Wavelength Range1528–1568nm
Insertion LossTransmitting end ≤4dB, receiving end ≤1.5dB
Switching Time<5ms (pure optical switching time)
Input Optical Power-25dBm to +21dBm
Optical Power Detection Accuracy±0.5dBm (at -25dBm or above)
Polarization Dependent Loss≤0.1dB
Isolation>50dB
Return Loss>45dB
Switching Cycles>107
Switching ConditionsRelative power difference and absolute power value
Switching ModeLocking, forced switching, manual switching and automatic switching supported
ReliabilityPower-off/power-on lockout, hot swap and master control failure do not affect protection switching
NameOptical Line Protection Card for DCI Chassis
Description1+1 optical layer protection card, 1 slot, 1 or 2 independent protection groups, each protecting a duplex fibre pair (bidirectional). Dual-transmit selective reception, single-end switching, <5ms pure optical switching time; 1528-1568nm; insertion loss ≤4dB (TX)/≤1.5dB (RX); input optical power -25 to +21dBm; isolation >50dB. Supports optical line 1+1 (OLP), optical multiplex section (OMSP) and optical channel (OCHP) protection scenarios.
Part NumberDCI-OLP-{Groups}-1S
{Groups}1 or 2, required - number of independent optical protection groups populated on the card