Skip to Content

MuxDemux Card for WDM Chassis

https://www.nexgen.eu/web/image/product.template/10458/image_1920?unique=9931463

The MuxDemux Card combines multiple optical channels onto a single fibre and separates them back out again, using thin-film filter technology. It is available in CWDM or DWDM (C-band, 100GHz) versions, with low insertion loss and high channel isolation across the full range. The same design supports single-fibre or dual-fibre line-side connections, and an optional combined power monitoring tap for centralised visibility of the multiplexed signal.

2 to 18 channels on one card

The same board design scales from 2 up to 18 optical channels, occupying 1 slot for 2/4/8 channels or 2 slots for 16/18 channels.

CWDM and DWDM versions

Available for CWDM (1271–1611nm) or DWDM C-band (100GHz spacing, ITU-T grid centre wavelengths).

Low insertion loss

From ≤1.2dB on the 2-channel version to ≤5.0dB on the 18-channel version, with ≤0.5dB flatness across channels.

High channel isolation

≥30dB adjacent-channel and ≥40dB non-adjacent-channel isolation, keeping crosstalk low as channel count increases.

Single or dual-fibre line side

Supports both single-fibre and dual-fibre application scenarios on the combined line-side interface.

Optional combined power monitoring

An optional monitoring tap reports combined signal power on the line side for centralised network management.

CH1CH2CHnMUXDEMUX⋮ChannelsCH1CH2CHnMUXDEMUX⋮ChannelsLine
CARD FOR WDM CHASSIS1 SLOTCARD FOR WDM CHASSIS2 SLOTS

0.00 kr 0.0 DKK 0.00 kr

  • xWDM
  • First Channel
  • Number of Channels
  • Monitoring

This combination does not exist.

Optical
Operating Wavelength RangeCWDM: 1271–1611nm · DWDM: C-band (100GHz)
Channel Centre WavelengthITU-T Grid
Number of Fibres on Line SideSupports single-fibre or dual-fibre line-side application scenarios
Flatness≤0.5dB
Adjacent Channel Isolation≥30dB
Non-Adjacent Channel Isolation≥40dB
Return Loss≥45dB
Directionality≥45dB
Channel Count ConfigurationOther channel counts available on request
Number of Optical Channels2481618
Channel Insertion Loss≤1.2dB≤1.8dB≤2.6dB≤4.5dB≤5.0dB
Number of Slots Occupied11122
Valid Start Channel, CWDM (ITU-T G.694.2, CH27–CH61 Step 2)CH27–CH59CH27–CH55CH27–CH47CH27–CH31, or fixed 16WP planCH27 (whole band)
Valid Start Channel, DWDM (ITU-T G.694.1, 100GHz Grid, CH21–CH61)CH21–CH60CH21–CH58CH21–CH54CH21–CH46CH21–CH44
 Slots given for the OTN WDM chassis range. CWDM channel numbers step by 2 (e.g. start CH27, count 4 → CH27,29,31,33); DWDM channel numbers step by 1 (e.g. start CH21, count 4 → CH21,22,23,24), see the CWDM and DWDM Channel Grid Reference tables below for wavelength/frequency per channel. The CWDM-only "16WP" plan is a {Channels} value with {Start} fixed at CH27: all 18 channels except CH39 (1391nm) and CH41 (1411nm), the two channels most affected by the fibre water-peak absorption band.
Management & Mechanical
Optical InterfaceLC/UPC
Power MonitoringCombined signal power monitoring (optional)
Maximum Power Consumption3W
ChannelWavelength
CH271271nm
CH291291nm
CH311311nm
CH331331nm
CH351351nm
CH371371nm
CH391391nm
CH411411nm
CH431431nm
CH451451nm
CH471471nm
CH491491nm
CH511511nm
CH531531nm
CH551551nm
CH571571nm
CH591591nm
CH611611nm

ITU-T G.694.1, 100GHz grid, C-band.

ChannelFrequencyWavelength
CH21196.1THz1528.77nm
CH22196.0THz1529.55nm
CH23195.9THz1530.33nm
CH24195.8THz1531.12nm
CH25195.7THz1531.9nm
CH26195.6THz1532.68nm
CH27195.5THz1533.47nm
CH28195.4THz1534.25nm
CH29195.3THz1535.04nm
CH30195.2THz1535.82nm
CH31195.1THz1536.61nm
CH32195.0THz1537.4nm
CH33194.9THz1538.19nm
CH34194.8THz1538.98nm
CH35194.7THz1539.77nm
CH36194.6THz1540.56nm
CH37194.5THz1541.35nm
CH38194.4THz1542.14nm
CH39194.3THz1542.94nm
CH40194.2THz1543.73nm
CH41194.1THz1544.53nm
CH42194.0THz1545.32nm
CH43193.9THz1546.12nm
CH44193.8THz1546.92nm
CH45193.7THz1547.72nm
CH46193.6THz1548.51nm
CH47193.5THz1549.32nm
CH48193.4THz1550.12nm
CH49193.3THz1550.92nm
CH50193.2THz1551.72nm
CH51193.1THz1552.52nm
CH52193.0THz1553.33nm
CH53192.9THz1554.13nm
CH54192.8THz1554.94nm
CH55192.7THz1555.75nm
CH56192.6THz1556.55nm
CH57192.5THz1557.36nm
CH58192.4THz1558.17nm
CH59192.3THz1558.98nm
CH60192.2THz1559.79nm
CH61192.1THz1560.61nm
NameMuxDemux Card for WDM Chassis
DescriptionMDU MuxDemux Card. Passive CWDM or DWDM multiplexer/demultiplexer using thin-film filter technology, with low insertion loss and high channel isolation. Supports single-fibre or dual-fibre line-side connections, with optional combined power monitoring.
Part NumberWDM-{xWDM}-{Start}-{Channels}[-M]-{Slots}S
{xWDM}CMD (CWDM MuxDemux) · DMD (DWDM MuxDemux), required
{Start}First channel number, CMD (CWDM): CH27–CH61, step 2 · DMD (DWDM): CH21–CH61, step 1, exact range depends on {Channels}, see Channel Count Configuration and Grid Reference tables above · for CMD only, fixed at CH27 when {Channels} is "16WP", required
{Channels}2 · 4 · 8 · 16 · 16WP (CMD only, fixed water-peak-optimised plan) · 18 (number of channels) (other channel counts available on request), required
[-M]omitted = without combined power monitoring · present = with combined power monitoring
{Slots}Sautomatically 1S for 2/4/8-channel configurations · 2S for 16/18-channel configurations, not independently selectable