MuxDemux Card for WDM Chassis
The MuxDemux Card combines multiple optical channels onto a single fibre and separates them back out again, using thin-film filter technology. It is available in CWDM or DWDM (C-band, 100GHz) versions, with low insertion loss and high channel isolation across the full range. The same design supports single-fibre or dual-fibre line-side connections, and an optional combined power monitoring tap for centralised visibility of the multiplexed signal.
Highlights
2 to 18 channels on one card
The same board design scales from 2 up to 18 optical channels, occupying 1 slot for 2/4/8 channels or 2 slots for 16/18 channels.
CWDM and DWDM versions
Available for CWDM (1271–1611nm) or DWDM C-band (100GHz spacing, ITU-T grid centre wavelengths).
Low insertion loss
From ≤1.2dB on the 2-channel version to ≤5.0dB on the 18-channel version, with ≤0.5dB flatness across channels.
High channel isolation
≥30dB adjacent-channel and ≥40dB non-adjacent-channel isolation, keeping crosstalk low as channel count increases.
Single or dual-fibre line side
Supports both single-fibre and dual-fibre application scenarios on the combined line-side interface.
Optional combined power monitoring
An optional monitoring tap reports combined signal power on the line side for centralised network management.
Functional Structure
Format
Specifications
| Optical | |||||
|---|---|---|---|---|---|
| Operating Wavelength Range | CWDM: 1271–1611nm · DWDM: C-band (100GHz) | ||||
| Channel Centre Wavelength | ITU-T Grid | ||||
| Number of Fibres on Line Side | Supports single-fibre or dual-fibre line-side application scenarios | ||||
| Flatness | ≤0.5dB | ||||
| Adjacent Channel Isolation | ≥30dB | ||||
| Non-Adjacent Channel Isolation | ≥40dB | ||||
| Return Loss | ≥45dB | ||||
| Directionality | ≥45dB | ||||
Channel Count ConfigurationOther channel counts available on request | |||||
| Number of Optical Channels | 2 | 4 | 8 | 16 | 18 |
| Channel Insertion Loss | ≤1.2dB | ≤1.8dB | ≤2.6dB | ≤4.5dB | ≤5.0dB |
| Number of Slots Occupied | 1 | 1 | 1 | 2 | 2 |
| Valid Start Channel, CWDM (ITU-T G.694.2, CH27–CH61 Step 2) | CH27–CH59 | CH27–CH55 | CH27–CH47 | CH27–CH31, or fixed 16WP plan | CH27 (whole band) |
| Valid Start Channel, DWDM (ITU-T G.694.1, 100GHz Grid, CH21–CH61) | CH21–CH60 | CH21–CH58 | CH21–CH54 | CH21–CH46 | CH21–CH44 |
| Slots given for the OTN WDM chassis range. CWDM channel numbers step by 2 (e.g. start CH27, count 4 → CH27,29,31,33); DWDM channel numbers step by 1 (e.g. start CH21, count 4 → CH21,22,23,24), see the CWDM and DWDM Channel Grid Reference tables below for wavelength/frequency per channel. The CWDM-only "16WP" plan is a {Channels} value with {Start} fixed at CH27: all 18 channels except CH39 (1391nm) and CH41 (1411nm), the two channels most affected by the fibre water-peak absorption band. | |||||
| Management & Mechanical | |||||
| Optical Interface | LC/UPC | ||||
| Power Monitoring | Combined signal power monitoring (optional) | ||||
| Maximum Power Consumption | 3W | ||||
CWDM Channel Grid Reference
| Channel | Wavelength |
|---|---|
| CH27 | 1271nm |
| CH29 | 1291nm |
| CH31 | 1311nm |
| CH33 | 1331nm |
| CH35 | 1351nm |
| CH37 | 1371nm |
| CH39 | 1391nm |
| CH41 | 1411nm |
| CH43 | 1431nm |
| CH45 | 1451nm |
| CH47 | 1471nm |
| CH49 | 1491nm |
| CH51 | 1511nm |
| CH53 | 1531nm |
| CH55 | 1551nm |
| CH57 | 1571nm |
| CH59 | 1591nm |
| CH61 | 1611nm |
DWDM Channel Grid Reference
ITU-T G.694.1, 100GHz grid, C-band.
| Channel | Frequency | Wavelength |
|---|---|---|
| CH21 | 196.1THz | 1528.77nm |
| CH22 | 196.0THz | 1529.55nm |
| CH23 | 195.9THz | 1530.33nm |
| CH24 | 195.8THz | 1531.12nm |
| CH25 | 195.7THz | 1531.9nm |
| CH26 | 195.6THz | 1532.68nm |
| CH27 | 195.5THz | 1533.47nm |
| CH28 | 195.4THz | 1534.25nm |
| CH29 | 195.3THz | 1535.04nm |
| CH30 | 195.2THz | 1535.82nm |
| CH31 | 195.1THz | 1536.61nm |
| CH32 | 195.0THz | 1537.4nm |
| CH33 | 194.9THz | 1538.19nm |
| CH34 | 194.8THz | 1538.98nm |
| CH35 | 194.7THz | 1539.77nm |
| CH36 | 194.6THz | 1540.56nm |
| CH37 | 194.5THz | 1541.35nm |
| CH38 | 194.4THz | 1542.14nm |
| CH39 | 194.3THz | 1542.94nm |
| CH40 | 194.2THz | 1543.73nm |
| CH41 | 194.1THz | 1544.53nm |
| CH42 | 194.0THz | 1545.32nm |
| CH43 | 193.9THz | 1546.12nm |
| CH44 | 193.8THz | 1546.92nm |
| CH45 | 193.7THz | 1547.72nm |
| CH46 | 193.6THz | 1548.51nm |
| CH47 | 193.5THz | 1549.32nm |
| CH48 | 193.4THz | 1550.12nm |
| CH49 | 193.3THz | 1550.92nm |
| CH50 | 193.2THz | 1551.72nm |
| CH51 | 193.1THz | 1552.52nm |
| CH52 | 193.0THz | 1553.33nm |
| CH53 | 192.9THz | 1554.13nm |
| CH54 | 192.8THz | 1554.94nm |
| CH55 | 192.7THz | 1555.75nm |
| CH56 | 192.6THz | 1556.55nm |
| CH57 | 192.5THz | 1557.36nm |
| CH58 | 192.4THz | 1558.17nm |
| CH59 | 192.3THz | 1558.98nm |
| CH60 | 192.2THz | 1559.79nm |
| CH61 | 192.1THz | 1560.61nm |
Ordering Information
| Name | MuxDemux Card for WDM Chassis |
| Description | MDU MuxDemux Card. Passive CWDM or DWDM multiplexer/demultiplexer using thin-film filter technology, with low insertion loss and high channel isolation. Supports single-fibre or dual-fibre line-side connections, with optional combined power monitoring. |
| Part Number | WDM-{xWDM}-{Start}-{Channels}[-M]-{Slots}S |
| {xWDM} | CMD (CWDM MuxDemux) · DMD (DWDM MuxDemux), required |
| {Start} | First channel number, CMD (CWDM): CH27–CH61, step 2 · DMD (DWDM): CH21–CH61, step 1, exact range depends on {Channels}, see Channel Count Configuration and Grid Reference tables above · for CMD only, fixed at CH27 when {Channels} is "16WP", required |
| {Channels} | 2 · 4 · 8 · 16 · 16WP (CMD only, fixed water-peak-optimised plan) · 18 (number of channels) (other channel counts available on request), required |
| [-M] | omitted = without combined power monitoring · present = with combined power monitoring |
| {Slots}S | automatically 1S for 2/4/8-channel configurations · 2S for 16/18-channel configurations, not independently selectable |
Netceed