DWDM OADM Module
The DWDM OADM Module is a passive thin-film-filter (TFF) optical add-drop multiplexer for DWDM network wavelength uplink/downlink applications. It operates on the ITU-T G.694.1 grid with 100GHz (0.8nm) channel spacing across 1525–1565nm, dropping and adding selected channels while passing the rest through transparently, with low insertion loss and high channel isolation.
Highlights
Low insertion loss
Thin-film-filter technology keeps both through-path and add/drop-path insertion loss low.
High channel isolation
≥30dB adjacent / ≥40dB non-adjacent channel isolation.
1 to 16 channels dropped
Five drop-count options, transparent pass-through for the remaining channels.
High stability & reliability
Conforms to ITU-T G.694.1 and Telcordia GR-1209/GR-1221.
Three package options
ABS box, LGX box or 1U rackmount, to match the installation style.
RoHS-6 compliant
Lead-free construction.
Format
Specifications
| Optical | |||
|---|---|---|---|
| Operating Wavelength Range | 1525–1565nm | ||
| Channel Center Wavelength | ITU-T grid | ||
| Channel Spacing | 100GHz (0.8nm) | ||
| Channel Bandwidth | ITU ±0.11nm | ||
| Flatness | ≤0.5dB | ||
| Adjacent Channel Isolation | ≥30dB | ||
| Non-Adjacent Channel Isolation | ≥40dB | ||
| Return Loss | ≥45dB | ||
| Directionality | ≥45dB | ||
| Polarization-Related Loss | ≤0.2dB | ||
| Polarization Mode Dispersion | ≤0.2ps | ||
| Maximum Withstanding Optical Power | ≤500mW | ||
| Environmental & Mechanical | |||
| Operating Temperature | 0°C–+70°C | ||
| Storage Temperature | −40°C–+85°C | ||
| Compliance | ITU-T G.694.1 · Telcordia GR-1209-CORE · Telcordia GR-1221-CORE · RoHS-6 | ||
| Package Type | ABS box · LGX box · 1U 19″ rackmount | ||
Channel Count
| Channel Count | Through-path insertion loss | Add/Drop-path insertion loss |
|---|---|---|
| 1 | ≤0.8dB | ≤0.8dB |
| 2 | ≤1.2dB | ≤1.2dB |
| 4 | ≤1.8dB | ≤2.0dB |
| 8 | ≤2.6dB | ≤3.2dB |
| 16 | ≤4.5dB | ≤5.3dB |
DWDM Channel Grid Reference
ITU-T G.694.1, 100GHz grid, C-band.
| Channel | Frequency | Wavelength |
|---|---|---|
| CH21 | 196.1THz | 1528.77nm |
| CH22 | 196.0THz | 1529.55nm |
| CH23 | 195.9THz | 1530.33nm |
| CH24 | 195.8THz | 1531.12nm |
| CH25 | 195.7THz | 1531.9nm |
| CH26 | 195.6THz | 1532.68nm |
| CH27 | 195.5THz | 1533.47nm |
| CH28 | 195.4THz | 1534.25nm |
| CH29 | 195.3THz | 1535.04nm |
| CH30 | 195.2THz | 1535.82nm |
| CH31 | 195.1THz | 1536.61nm |
| CH32 | 195.0THz | 1537.4nm |
| CH33 | 194.9THz | 1538.19nm |
| CH34 | 194.8THz | 1538.98nm |
| CH35 | 194.7THz | 1539.77nm |
| CH36 | 194.6THz | 1540.56nm |
| CH37 | 194.5THz | 1541.35nm |
| CH38 | 194.4THz | 1542.14nm |
| CH39 | 194.3THz | 1542.94nm |
| CH40 | 194.2THz | 1543.73nm |
| CH41 | 194.1THz | 1544.53nm |
| CH42 | 194.0THz | 1545.32nm |
| CH43 | 193.9THz | 1546.12nm |
| CH44 | 193.8THz | 1546.92nm |
| CH45 | 193.7THz | 1547.72nm |
| CH46 | 193.6THz | 1548.51nm |
| CH47 | 193.5THz | 1549.32nm |
| CH48 | 193.4THz | 1550.12nm |
| CH49 | 193.3THz | 1550.92nm |
| CH50 | 193.2THz | 1551.72nm |
| CH51 | 193.1THz | 1552.52nm |
| CH52 | 193.0THz | 1553.33nm |
| CH53 | 192.9THz | 1554.13nm |
| CH54 | 192.8THz | 1554.94nm |
| CH55 | 192.7THz | 1555.75nm |
| CH56 | 192.6THz | 1556.55nm |
| CH57 | 192.5THz | 1557.36nm |
| CH58 | 192.4THz | 1558.17nm |
| CH59 | 192.3THz | 1558.98nm |
| CH60 | 192.2THz | 1559.79nm |
| CH61 | 192.1THz | 1560.61nm |
Ordering Information
| Name | DWDM OADM Module |
| Description | DWDM OADM Module, passive thin-film-filter (TFF) optical add-drop multiplexer for DWDM wavelength uplink/downlink applications, ITU-T G.694.1 grid, 100GHz (0.8nm) channel spacing, 1525-1565nm. Drops and adds selected channels while passing the rest through transparently. |
| Part Number | WDM-DOADM-{Start}-{Channels}-{Format} |
| {Start} | First dropped channel number, CH21–CH61 (ITU-T G.694.1 100GHz grid, step 1), see grid reference table above, required |
| {Channels} | 1 · 2 · 4 · 8 · 16, see Channel Count table above, required |
| {Format} | ABS (ABS box) · LGX (LGX box) · 1U (1U rackmount), required |